The ABF is the product that with small diameter, lightweight, highly flexibility and proper stiffness, and it can be blown into the microduct of 5.0/3...
The ABF is the product that with small diameter, lightweight, highly flexibility and proper stiffness, and it can be blown into the microduct of 5.0/3.5mm. The fibres are coated with a soft acrylate resin which provides excellent dimensional and thermal stability to cushion the fibres, in addition, the resin can be easily stripped in connecting the fibres. The outer sheath is a thermoplastic that is of low friction. The surface of the sheath is designed with special grooves, compared to the surface of the traditional optical fibre cable, it provides not only the high level of mechanical protection, but also the perfect blowing performance.
Features and Benefits
- 2,4,6,8 and 12 fibers options.
- Stable structure, good mechanical and temperature performance.
- Designed with special grooves to advance blowing distance.
- Lightweight and proper stiffness , repeat installation.
- Designed with no gel, easy stripping and handling.
- Better costs advantage compared to traditional product.
- Complete accessories, less manpower, lower installation time.
Standards
Unless otherwise specified in this specification, all requirements shall be mainly in accordance with the following standard specifications. Optical Fibre TU-T G.652 , G.657 IEC 60793-2-50 Optica Cable ……IEC 60794 1-2,IEC 60794-5
Fibre Count | 2 Fibres | 4 Fibres | 6 Fibres | 8 Fibres | 12 Fibres |
Outer Diameter (mm) | 1.15±0.05 | 1.15±0.05 | 1.35±0.05 | 1.50±0.05 | 1.65±0.05 |
Weight(g/m) | 1.0 | 1.0 | 1.3 | 1.8 | 2.2 |
Min Bend radius(mm) | 50 | 50 | 60 | 80 | 80 |
Temperature | Storage:-30℃ ~ +70℃ Operation:-30℃ ~ +70℃ Installation:-5℃ ~ +50℃ |
Cable service life (estimate value) | 25 years |
Note: It is recommended that the structure of 2 fibres unit consist of 2 filled fibres, for it is provedthat 2 fibres unit with 2 filled fibres is better than the one with zero or one filled fibre in the blowing performance and the fibre stripping-ability |
Fibre Count | 2 Fibres | 4 Fibres | 6 Fibres | 8 Fibres | 12 Fibres |
Test equipment | PLUMETTAZ:UM25, ERICSSON:F, CATWAY:FBT-1.1 |
Standard duct | 5.0/3.5 mm |
Pressure | 7bar / 10bar |
Typical blowing distance | 500m / 1000 m | 500m / 1000m | 500m / 1000m | 500m / 1000m | 500m / 800m |
Typical blowing time | 10 min/18 min | 10 min18 min | 12 min/ 18 min | 13min/18 min | 15 min /20 min |
Test | Standard | Parameters | Test Results |
Tension | EN 18700 A1/501 IEC 60794-1-2-E1 | Load is 1×W | Additional attenuation ≤0.05dB after test |
Bend | IEC 60794-1-2--E11A | Diam 40mm×3turns 5 cycles at 20℃ | Additional attenuation ≤0.05dB,after test |
Crush | IEC 60794-1-2-E3 | 100 N, 60s | Additional attenuation ≤0.05dB,after test |
All optical testing proceeded at 1550 nm |
Fibre Count | Length(m) | Pan Size Φ×H(mm) | Weight (Gross) (kg) |
2~4 Fibres | 2000 m | φ510 × 200 | 8.0 |
| 4000 m | φ510 × 200 | 10.0 |
| 6000m | φ510 × 300 | 13.0 |
6 Fibres | 2000 m | φ510 × 200 | 9.0 |
| 4000 m | φ510 × 300 | 12.0 |
8 Fibres | 2000 m | φ510 × 200 | 9.0 |
| 4000 m | φ510 × 300 | 14.0 |
12 Fibres | 1000 m | φ510 × 200 | 8.0 |
| 2000 m | φ510 × 200 | 10.0 |
| 3000m | φ510 × 300 | 14.0 |
| 4000 m | φ510 × 300 | 15.0 |